Heat blocks and circuits | up to 20 kW | mixed | without the possibility of fitting a heat meter

Mixed boiler circuit HPW-MFN up to 20 KW to maintain constant flow temperature with programming unit and three-speed pump

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm AVANSA 25-6-180 pump electronic programmable ROTOTEMP C unit to maintain a constant flow temperature

kúpiť

Mixed boiler circuit HPW-MFN up to 20 KW for maintaining constant flow temperature with program unit and electronic pump

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm DAB Evosta 40 - 70/180 pump electronic programmable unit ROTOTEMP C to maintain a constant flow temper

kúpiť

Mixed boiler set HPW-MN with servo drive without pump up to 20kW Type: Mixed boiler set HPW-MN with servo drive without pump up to 20kW 0-10 V…

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm without pump /L= 180 mm/ FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessorie

kúpiť

Mixed boiler set HPW-MN with servo drive without pump up to 20kW Type: Mixed boiler set HPW-MN with servo drive without pump up to 20kW 230 V

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm without pump /L= 180 mm/ FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessorie

kúpiť

Mixed boiler set HPW-MN with servo drive without pump up to 20kW Type: Mixed boiler set HPW-MN with servo drive without pump up to 20kW 24 V

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm without pump /L= 180 mm/ FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessorie

kúpiť

Mixed boiler set HPW-MN with servo drive and three-speed pump up to 20kW Type: Mixed boiler set HPW-MN with servo drive and three-speed pump up to…

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm AVANSA 25-6-180 pump FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessories f

kúpiť

Mixed boiler set HPW-MN with servo drive and electronic pump up to 20kW Type: Mixed boiler set HPW-MN with servo drive and electronic pump up to 20kW…

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm DAB Evosta 40-70/180 pump FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessorie

kúpiť

Mixed boiler set HPW-MN without servo drive without pump up to 20kW

Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm without actuator without pump /L=180 mm/ Select the necessary accessories for wiring: